Case Report One-lung Ventilation using Wire-guided Endobronchial Blocker and Single Lumen Endotracheal Tube: A Case Report
Hee Zoo Kim, Seung Hwan Oh, Chung Guk Park, Eun Hye Koo, Hye Ran Oh, Mi Kyoung Lee, Sang Ho Lim

DOI: https://doi.org/
Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea. andigi@korea.ac.kr
  • 1,784 Views
  • 12 Download
  • 0 Crossref
  • 0 Scopus

We had done one-lung ventilation using 9 Fr wire-guided endobronchial blocker and outer diameter 41-mm flexible fiberoptic bronchoscope in ruptured esophageal patient who expected difficult tracheal intubation and in esophageal cancer patient who was in need of mechanical ventilation during and after the operation.